Short answer: MCCB stands for Moulded Case Circuit Breaker, VFD for Variable Frequency Drive and ACB for Air Circuit Breaker. The table below lists the full forms used most often in switchgear, panels, motor control and testing, with what each one does.
Circuit breaker and protection full forms
Short form | Full form | What it does |
|---|---|---|
MCB | Miniature Circuit Breaker | Protects final circuits, typically up to 63 A or 125 A. See MCB. |
MCCB | Moulded Case Circuit Breaker | Breaker in a moulded case, about 16 A to 1,600 A. See MCCB. |
ACB | Air Circuit Breaker | High-current incomer breaker, about 630 A to 6,300 A. See air circuit breakers. |
VCB | Vacuum Circuit Breaker | Medium-voltage (HT) breaker that interrupts the arc in vacuum. |
RCCB | Residual Current Circuit Breaker | Trips on earth leakage to protect people. See RCCB. |
RCBO | Residual Current Breaker with Overcurrent protection | RCCB and MCB in one device. See RCBO. |
ELCB | Earth Leakage Circuit Breaker | Older term for earth leakage protection; see ELCB vs RCCB. |
MPCB | Motor Protection Circuit Breaker | Motor overload and short-circuit protection. See MPCB. |
SPD | Surge Protection Device | Diverts surges away from equipment. See SPD. |
HRC | High Rupturing Capacity (fuse) | Fuse able to clear high fault currents. See HRC fuses. |
SFU | Switch Fuse Unit | Switch and fuses combined for isolation and protection. |
OLR | Overload Relay | Trips a motor contactor on sustained overcurrent. |
Panel full forms
Short form | Full form | What it does |
|---|---|---|
LT panel | Low Tension panel | Low-voltage (up to 1,000 V, typically 415 V) distribution board. See LT panels. |
HT panel | High Tension panel | Switchgear for 3.3 kV and above. |
PCC | Power Control Centre | Main LT panel that receives and distributes power. See PCC panels. |
MCC | Motor Control Centre | Panel of motor feeders with starters and controls. See MCC panels. |
APFC | Automatic Power Factor Control (Correction) | Switches capacitors to hold power factor. See APFC panels. |
AMF | Auto Mains Failure | Starts the DG and transfers load on mains failure. See AMF panels. |
ATS | Automatic Transfer Switch | Transfers load between two sources. See ATS. |
PDB | Power Distribution Board | Sub-distribution board with MCCB feeders. See PDB. |
DB | Distribution Board | Final-circuit board with MCBs. See distribution boards. |
PLC panel | Programmable Logic Controller panel | Automation panel built around a PLC. See PLC panels. |
Motor control and automation full forms
Short form | Full form | What it does |
|---|---|---|
VFD | Variable Frequency Drive | Controls motor speed by varying frequency and voltage. See what is a VFD. |
DOL | Direct On Line (starter) | Starts a motor at full voltage. See DOL starter diagram. |
PLC | Programmable Logic Controller | Industrial computer that runs control logic. |
HMI | Human Machine Interface | Operator touch screen for a machine or process. |
SCADA | Supervisory Control and Data Acquisition | Plant-wide monitoring and control. See SCADA systems. |
SMPS | Switched Mode Power Supply | Efficient AC-to-DC power supply. See SMPS. |
UPS | Uninterruptible Power Supply | Battery-backed supply for critical loads. |
SSR | Solid State Relay | Relay with no moving contacts. See solid state relays. |
Cable, power quality and testing full forms
Short form | Full form | Meaning |
|---|---|---|
XLPE | Cross-Linked Polyethylene | Cable insulation rated 90 °C. See XLPE vs PVC. |
FRLS | Flame Retardant Low Smoke | Cable sheath that limits flame spread and smoke. |
CT / PT | Current Transformer / Potential Transformer | Scale current or voltage for meters and relays. See CT vs PT. |
kVAr | kilovolt-ampere reactive | Unit of reactive power; capacitors are rated in kVAr. |
PF | Power Factor | Ratio of real power (kW) to apparent power (kVA). |
THD | Total Harmonic Distortion | Measure of waveform distortion from non-linear loads. |
IR / PI | Insulation Resistance / Polarisation Index | Insulation tests; see IR vs PI. |
TTR | Transformer Turns Ratio | Ratio test on transformers; see TTR test. |
BDV | Breakdown Voltage | Dielectric strength of insulating oil; see oil BDV test. |
Need any of these?
Tirupati Power Enterprises supplies switchgear, starters and drives from Kolkata and manufactures LT, PCC, MCC, APFC, AMF and PLC panels at its own works. Send your BOQ or part numbers for a line-by-line quotation.
Frequently asked questions
What is the full form of MCCB?
Moulded Case Circuit Breaker.
What is the full form of VFD?
Variable Frequency Drive, also called an AC drive or inverter.
What is the full form of ACB?
Air Circuit Breaker.
What is the full form of APFC panel?
Automatic Power Factor Control (or Correction) panel.
What is the full form of LT panel?
Low Tension panel, meaning a low-voltage distribution panel.