Short answer: MCCB stands for Moulded Case Circuit Breaker, VFD for Variable Frequency Drive and ACB for Air Circuit Breaker. The table below lists the full forms used most often in switchgear, panels, motor control and testing, with what each one does.

Circuit breaker and protection full forms

Short form

Full form

What it does

MCB

Miniature Circuit Breaker

Protects final circuits, typically up to 63 A or 125 A. See MCB.

MCCB

Moulded Case Circuit Breaker

Breaker in a moulded case, about 16 A to 1,600 A. See MCCB.

ACB

Air Circuit Breaker

High-current incomer breaker, about 630 A to 6,300 A. See air circuit breakers.

VCB

Vacuum Circuit Breaker

Medium-voltage (HT) breaker that interrupts the arc in vacuum.

RCCB

Residual Current Circuit Breaker

Trips on earth leakage to protect people. See RCCB.

RCBO

Residual Current Breaker with Overcurrent protection

RCCB and MCB in one device. See RCBO.

ELCB

Earth Leakage Circuit Breaker

Older term for earth leakage protection; see ELCB vs RCCB.

MPCB

Motor Protection Circuit Breaker

Motor overload and short-circuit protection. See MPCB.

SPD

Surge Protection Device

Diverts surges away from equipment. See SPD.

HRC

High Rupturing Capacity (fuse)

Fuse able to clear high fault currents. See HRC fuses.

SFU

Switch Fuse Unit

Switch and fuses combined for isolation and protection.

OLR

Overload Relay

Trips a motor contactor on sustained overcurrent.

Panel full forms

Short form

Full form

What it does

LT panel

Low Tension panel

Low-voltage (up to 1,000 V, typically 415 V) distribution board. See LT panels.

HT panel

High Tension panel

Switchgear for 3.3 kV and above.

PCC

Power Control Centre

Main LT panel that receives and distributes power. See PCC panels.

MCC

Motor Control Centre

Panel of motor feeders with starters and controls. See MCC panels.

APFC

Automatic Power Factor Control (Correction)

Switches capacitors to hold power factor. See APFC panels.

AMF

Auto Mains Failure

Starts the DG and transfers load on mains failure. See AMF panels.

ATS

Automatic Transfer Switch

Transfers load between two sources. See ATS.

PDB

Power Distribution Board

Sub-distribution board with MCCB feeders. See PDB.

DB

Distribution Board

Final-circuit board with MCBs. See distribution boards.

PLC panel

Programmable Logic Controller panel

Automation panel built around a PLC. See PLC panels.

Motor control and automation full forms

Short form

Full form

What it does

VFD

Variable Frequency Drive

Controls motor speed by varying frequency and voltage. See what is a VFD.

DOL

Direct On Line (starter)

Starts a motor at full voltage. See DOL starter diagram.

PLC

Programmable Logic Controller

Industrial computer that runs control logic.

HMI

Human Machine Interface

Operator touch screen for a machine or process.

SCADA

Supervisory Control and Data Acquisition

Plant-wide monitoring and control. See SCADA systems.

SMPS

Switched Mode Power Supply

Efficient AC-to-DC power supply. See SMPS.

UPS

Uninterruptible Power Supply

Battery-backed supply for critical loads.

SSR

Solid State Relay

Relay with no moving contacts. See solid state relays.

Cable, power quality and testing full forms

Short form

Full form

Meaning

XLPE

Cross-Linked Polyethylene

Cable insulation rated 90 °C. See XLPE vs PVC.

FRLS

Flame Retardant Low Smoke

Cable sheath that limits flame spread and smoke.

CT / PT

Current Transformer / Potential Transformer

Scale current or voltage for meters and relays. See CT vs PT.

kVAr

kilovolt-ampere reactive

Unit of reactive power; capacitors are rated in kVAr.

PF

Power Factor

Ratio of real power (kW) to apparent power (kVA).

THD

Total Harmonic Distortion

Measure of waveform distortion from non-linear loads.

IR / PI

Insulation Resistance / Polarisation Index

Insulation tests; see IR vs PI.

TTR

Transformer Turns Ratio

Ratio test on transformers; see TTR test.

BDV

Breakdown Voltage

Dielectric strength of insulating oil; see oil BDV test.

Need any of these?

Tirupati Power Enterprises supplies switchgear, starters and drives from Kolkata and manufactures LT, PCC, MCC, APFC, AMF and PLC panels at its own works. Send your BOQ or part numbers for a line-by-line quotation.

Frequently asked questions

What is the full form of MCCB?

Moulded Case Circuit Breaker.

What is the full form of VFD?

Variable Frequency Drive, also called an AC drive or inverter.

What is the full form of ACB?

Air Circuit Breaker.

What is the full form of APFC panel?

Automatic Power Factor Control (or Correction) panel.

What is the full form of LT panel?

Low Tension panel, meaning a low-voltage distribution panel.