Miniature circuit breakers for overload and short-circuit protection of final circuits, 0.5 to 63 A, in B, C and D curves.

Rated current
0.5 A to 63 A (some ranges to 125 A)
Trip curves
B (3–5 × In), C (5–10 × In), D (10–20 × In)
Breaking capacity
6 kA and 10 kA typical; higher in industrial ranges
Poles
SP, SP+N, DP, TP, TPN, 4P

Buying several items? Upload your BOQ

  • Electrical supply since 1991
  • Leading makes, or the one you specify
  • GST invoice · delivery across India

About MCB (Miniature Circuit Breakers)

An MCB (miniature circuit breaker) automatically switches off a circuit when it detects an overload or a short circuit, and can be reset after the fault is cleared. It replaces rewireable fuses in distribution boards for lighting, sockets, small motors and control circuits.

Selection comes down to four things: rated current, trip curve (B, C or D), breaking capacity (typically 6 kA or 10 kA) and number of poles. MCBs for homes and buildings follow IEC/IS 60898-1; industrial versions are also tested to IEC 60947-2.

TPE quotes MCBs from Kolkata in every major make, from single pieces to full DB schedules, with delivery across India.

Where each circuit also needs earth leakage protection, use an RCBO. For board sizes and ways see the MCB box size guide.

For solar and battery DC circuits use DC MCBs, not AC MCBs.

  • Choose the trip curveB for resistive and lighting loads, C for general and small motor loads, D for high inrush such as transformers and motors.
  • 6 kA and 10 kA breakingStandard and industrial breaking capacities to suit the fault level at the board.
  • Every pole configurationSP, SP+N, DP, TP, TPN and 4P for single- and three-phase circuits.
  • 14 approved makesSchneider, ABB, Siemens, L&T, Havells, Legrand, Hager and more, priced side by side.

Specifications

Rated current0.5 A to 63 A (some ranges to 125 A)
Trip curvesB (3–5 × In), C (5–10 × In), D (10–20 × In)
Breaking capacity6 kA and 10 kA typical; higher in industrial ranges
PolesSP, SP+N, DP, TP, TPN, 4P
StandardsIEC/IS 60898-1; IEC 60947-2 for industrial ranges
Mounting35 mm DIN rail

Applications

Distribution boards

Outgoing protection for lighting, socket and small power circuits.

Control panels

Protection for control supplies, PLCs and instruments.

Small motors

C or D curve MCBs for pumps, fans and compressors.

Commercial buildings

Final-circuit protection in offices, shops and hospitals.

How to choose

  1. Rated current

    Choose a rating at or above the circuit's load current and at or below the cable's current capacity.

  2. Trip curve

    Match the curve to the load's inrush: B, C or D.

  3. Breaking capacity

    Make sure it exceeds the prospective fault current at the board.

  4. Poles and make

    Pick the pole configuration and the make approved for your project.

MCB vs MCCB vs RCCB

MCB vs MCCB vs RCCB
DeviceProtects againstTypical range
MCBOverload and short circuit0.5–63 A, 6–10 kA
MCCBOverload and short circuit, higher currents16–1600 A, 25–150 kA
RCCBEarth leakage (shock and fire)25–100 A, 30/100/300 mA
RCBOOverload, short circuit and earth leakage6–40 A typical

Makes we can quote

Quoted in the makes below and any other make on your approved list.

Frequently asked questions

What is the full form of MCB?

MCB stands for Miniature Circuit Breaker: a compact breaker, typically up to 63 A or 125 A, that protects final circuits against overload and short circuit.

What is the difference between B, C and D curve MCBs?

They trip instantaneously at different multiples of rated current: B at 3–5 ×, C at 5–10 × and D at 10–20 ×. Use B for resistive loads, C for general and small motor loads, D for high-inrush loads.

MCB or MCCB: which do I need?

MCBs cover up to about 63 A with modest breaking capacity. Above that, or where the fault level is high, use an MCCB.

Does an MCB protect against electric shock?

No. An MCB protects against overload and short circuit. For shock protection use an RCCB or an RCBO.

What breaking capacity should I choose?

6 kA is common in homes and small buildings; 10 kA or more in commercial and industrial boards. It must exceed the prospective fault current.

How do I order MCBs?

Send the rating, curve, poles, breaking capacity, make and quantity, or your DB schedule.

Industries that use MCB (Miniature Circuit Breakers)

Commercial buildings

Final-circuit protection in DBs for lighting and sockets.

Panel builders

Control-supply and auxiliary circuit protection.

Plants

Protection for small motors and process equipment.

Get a quote for MCB (Miniature Circuit Breakers)

Tell us the grade, size, form and quantity, or attach a drawing, BOQ or photo of the existing item. We reply with a line-by-line quotation from Kolkata, with delivery across India.

  1. Send your requirement Grade, size, quantity, or a BOQ, drawing or photo.
  2. We confirm and quote Matching make and grade, price and dispatch date, line by line.
  3. Dispatch from Kolkata With GST invoice, delivered to your site across India.
Prefer WhatsApp?
PDF, Excel, Word, CSV, images · 5 files · 4 MB
Add email or phone so we can reply.
Add company name (optional)
Files are sent privately to our sales team.