Electrical panel manufacturing

Tirupati Power Enterprises is an electrical panel manufacturer in Kolkata. We design and build custom LT, PCC, MCC, APFC, ACB, PLC, AMF and drive control panels to your single-line diagram and approved makes, for plants and projects across India.

  • Electrical supply since 1991
  • Own panel works in Kolkata
  • Delivery across India
LT power control centre panel with ACB incomers
Representative panel type. Design, component makes and testing are confirmed for each project.

Why buy electrical panels from TPE

A panel manufacturer and an electrical stockist in one company, so the panel and everything around it can come from one order.

Built to your SLD

Every panel is engineered from your single-line diagram, load schedule and fault level, not a standard catalogue box.

Your approved makes

Switchgear and components in the makes on your approved list: L&T, Schneider, Siemens, ABB and others.

Drawings for approval

GA, wiring and bill of materials are sent for your approval before fabrication starts.

Checked before dispatch

Wiring, interlocks and functions are checked against the approved drawings, with inspection points agreed with you.

Panel and supply from one source

As a stockist too, we supply the cables, glands, lugs and accessories for the installation on the same order.

Delivered across India

Manufactured in Kolkata and dispatched to sites across India, with a GST invoice.

Panel construction options

Every panel is built to your specification. These are the construction choices to state in the enquiry; we confirm each one on the GA drawing for approval.

What to specifyCommon options
Internal separationForm 1, 2, 3 or 4 (with a or b variants) between busbars, functional units and terminals.
Degree of protectionIP42 to IP55 indoor; IP55 or IP65 for dusty, damp or outdoor locations.
Short-circuit ratingBusbars and supports sized to the prospective fault level, for example 25, 36 or 50 kA for 1 s.
Sheet steelCRCA sheet, commonly 1.6 mm for doors and covers and 2 mm for frames and gland plates.
FinishPre-treated and powder coated, typically RAL 7032 or RAL 7035, or the shade you specify.
BusbarsCopper or aluminium, sleeved or bare, rated to the incomer with neutral and earth bars.
Cable entryTop or bottom entry, detachable gland plates, cable alleys for MCC and PCC feeders.
Mounting and accessFloor-standing or wall-mounted, front or front-and-rear access, indoor or outdoor canopy.

How we build your electrical panel

Four stages from your drawings to a tested panel on your site.

  1. 01

    Define

    You share the SLD, load or motor schedule, fault level, approved makes and site details.

  2. 02

    Engineer

    We prepare the GA drawing, BOM, busbar sizing, protection and control logic for approval.

  3. 03

    Build

    Sheet-metal fabrication, busbar work, component mounting and labelled, ferruled wiring at our works.

  4. 04

    Test & dispatch

    Functional and wiring checks to the agreed plan, inspection if required, then packing and dispatch.

Switchgear makes we build with

Electrical panels built to your drawings with switchgear and control components from the makes on your approved list, including those below. Any other specified make is quoted on request.

The specification schedule behind a reliable panel quotation

Send the latest single-line diagram (SLD), bill of quantities (BOQ) and load or feeder schedule, and say which drawings are for quotation and which are approved for manufacture. If something is not decided yet, mark it open; we will raise it in the offer rather than assume it.

Current rating alone does not define a panel. Supply system, fault level, operating arrangement, site environment and connected loads all shape the busbars, protection, enclosure and cooling. The table lists what to send and what we agree with you before manufacture.

Panel RFQ information: electrical, mechanical and control scope
RequirementInclude in the enquiryAgree before manufacture
Supply and loadingSystem voltage, frequency, phases, earthing system and load schedule.Incomer/outgoing arrangement, diversity assumptions and future capacity.
Fault duty and protectionProspective fault current, required withstand duty and protection philosophy.Assembly duty, protective devices, settings responsibility and coordination scope.
Busbars and feedersMaterial requirement, circuit ratings, neutral/PE needs and cable details.Busbar arrangement, terminations and feeder schedule.
EnclosureIndoor/outdoor duty, IP requirement, access, entry, footprint and installation constraints.Material, finish, separation, cooling and maintainable layout.
Components and controlsApproved makes, metering, control voltage, sequence and I/O/communication.Bill of materials (BOM), logic, interfaces and permitted equivalents.
Acceptance and deliveryApplicable specification/edition, drawings, inspection, documentation and destination.Verification evidence, witness points, FAT scope, packing and any site-support scope.

Enclosure, construction and access

Specify the enclosure material and thickness, finish or paint system, colour, cable entry direction, front or rear access, overall footprint and transport constraints. If CRCA/mild steel or a particular stainless-steel grade is required, state it in the brief. Include the environment: temperature, dust, moisture, corrosive exposure or outdoor installation may change the enclosure and thermal-management requirements.

For motor and drive panels, identify the starting method, load duty and interlocks. For PLC systems, include the operating sequence, signal types and interfaces with field equipment. For APFC, provide measurements and harmonic information before selecting the capacitor-bank arrangement; a connected-load total alone is not a complete design brief.

The GA drawing we send for approval settles service access, wiring space, component labels and cable interfaces. It also records what is in our supply and what the installation contractor provides, such as external cables, foundations and site work.

Drawings, testing and handover documents

Name the project specification and the standard your consultant or client requires, for example IEC 61439 for low-voltage assemblies, so the design, tests and records are planned against it from the start.

We agree the inspection and test plan with you before manufacture. If your project needs independent type-test reports, list them in the enquiry so the scope and acceptance are confirmed in the quotation.

  • Approved SLD, general arrangement (GA), BOM and control/wiring drawings.
  • Relevant design-verification evidence and agreed routine-verification records.
  • Functional checks against the approved sequence, interlocks and indication.
  • Any factory acceptance test (FAT), witness points and agreed test/report scope.
  • As-built drawings, labels, component references and agreed handover documents.

What determines an electrical panel price?

Panel price depends on feeder count and ratings, fault duty, busbar construction, component makes, enclosure size and finish, controls, metering, cooling and the agreed inspection/documentation scope. Two quotations headed “MCC panel” can describe materially different assemblies.

Compare quotations on the bill of materials, not the heading: makes, quantities, busbar size, enclosure, exclusions, packing, taxes, freight and any commissioning. Our quotation itemises these, with the delivery schedule tied to drawing approval and the agreed inspection.

New project or replacement? Send the right starting documents

For a new project, send the SLD, load/feeder schedule, approved makes and site layout. Include the operating philosophy for controls and automation. If a consultant specification applies, attach it with the drawing revision so the technical and commercial proposal refers to the same scope.

For a replacement, send existing drawings or nameplate photographs, dimensions, cable positions and the functions that must stay or change. A front photograph helps us identify the arrangement; fault level and protection settings come from your drawings.

For an extension, we review the busbars, heat load and cable space of the whole revised panel, not only the added feeders, so the extension fits the existing assembly.

Make your enquiry ready to price

A blank feeder and project schedule covering ratings, fault duty, enclosure, controls, drawings, inspection and destination.

Download electrical panel RFQ sheet (CSV)

Fill the sheet and attach it to your enquiry. Your own BOQ or drawing is equally useful.

Check the commercial scope

Ask the quotation to identify the proposed construction or make, quantities and units, availability, price, taxes, freight and lead time. Review exclusions and any alternatives before placing the order.

Inspect your panel at our works

Panels are fabricated, wired and checked at our own works in Kolkata. You or your consultant can inspect the panel against the approved drawings and witness agreed tests before dispatch; set the inspection points in the order.

  • Stage inspection during fabrication and wiring
  • Witness of agreed functional and wiring checks
  • As-built drawings and labels handed over with the panel

Panel works31A, Pulin Khatick Road, Kolkata 700015

Book an inspection with your orderDiscuss your panel on WhatsApp ↗

Electrical panel manufacturing: FAQs

Can you extend or modify an existing panel?

Yes. Send the existing drawings or photographs, nameplate details and the feeders to add. We review the busbars, heat load and cable space of the whole revised panel before quoting the extension or a replacement.

Which form of separation should I choose for an MCC or PCC?

It depends on how much of the panel must stay live during maintenance. Form 2 separates busbars from functional units; Form 3b and Form 4 also separate each feeder and its terminals, which suits MCCs where feeders are worked on while others run. State the form your consultant specifies.

What types of electrical panels do you manufacture?

LT and PCC panels, MCC and starter panels, APFC panels (conventional and thyristor), ACB panels, PLC and relay control panels, AMF and synchronising panels, drive panels, distribution boards, feeder pillars, control desks, mimic panels, bus ducts and junction boxes.

Can I inspect my panel before dispatch?

Yes. Inspection points and any witness tests at our Kolkata works can be agreed in the quotation, so you or your consultant can check the panel against the approved drawings before it ships.

Does TPE manufacture electrical panels in Kolkata?

Yes. Tirupati Power Enterprises manufactures custom electrical panels and accessories in Kolkata. The catalogue includes PCC, motor-control, APFC, PLC, drive-control and generator synchronisation/AMF requirements. Design, ratings, components and acceptance scope are confirmed for each project.

What is the difference between a PCC and an MCC panel?

A PCC primarily distributes incoming power to outgoing feeders. An MCC groups motor starting, protection and control functions. A plant may need both; the single-line diagram, load schedule and operating requirements establish the appropriate arrangement.

Can you quote an APFC, PLC or generator-control panel?

Send the application-specific brief. APFC needs load/power-factor and harmonic information; PLC requires the sequence and I/O/interfaces; generator control needs ratings, mains/generator arrangement and operating philosophy. The team confirms the proposed scope and any missing inputs.

Which brands of switchgear can be used?

Include your approved-make list and any required series or part references. The BOM and quotation identify the proposed components and any alternatives for approval.

Can you provide test reports for a panel?

Include any required type-test reports or standard in your enquiry. We confirm the test and documentation scope for your panel in the quotation.

What drawings and documents should accompany the order?

Agree the SLD, GA, BOM, wiring/control drawings, inspection plan, applicable verification records and handover requirements. State any FAT or witness points before the quotation is finalised so they form part of the accepted scope.

Do you supply outside Kolkata?

TPE serves electrical procurement from Kolkata with shipping across India. Include the delivery PIN code and site constraints. Freight, packing, delivery terms and any site work or support are confirmed in the project quotation.

What is the price, warranty and delivery time for a panel?

These depend on the approved design, ratings, feeder count, component selection, enclosure, inspection scope and destination. TPE confirms pricing, warranty, availability, payment and delivery terms in the quotation; there is no single rate or dispatch period for every custom assembly.

Get a quote for your electrical panel

Attach your SLD, BOQ, feeder schedule or replacement reference. Include approved makes, site conditions, inspection requirements and delivery location.

  1. Send your drawings SLD, BOQ, load or motor schedule and approved makes.
  2. We engineer and quote Itemised BOM, drawings for approval and delivery schedule.
  3. Build and dispatch Manufactured and checked in Kolkata, delivered to your site.
Prefer WhatsApp?
PDF, Excel, Word, CSV, images · 5 files · 4 MB
Add email or phone so we can reply.
Add company name (optional)
Files are sent privately to our sales team.