Per-circuit shock protection.

RCBO
RCBOs (RCCB + MCB in one) for earth leakage, overload and short-circuit protection of final circuits, 6–63 A, 30 to 300 mA.
- Current rating
- 6, 10, 16, 20, 25, 32, 40, 63 A
- Sensitivity (IΔn)
- 10, 30, 100, 300 mA
- Type
- AC or A (A for electronic and inverter loads)
- Curve
- B or C
Buying several items? Upload your BOQ
- Electrical supply since 1991
- Leading makes, or the one you specify
- GST invoice · delivery across India
About RCBO
RCBO stands for Residual Current Breaker with Overcurrent protection. It combines an RCCB (trips on earth leakage) and an MCB (trips on overload and short circuit) in one device, so each circuit gets its own leakage protection. A fault on one circuit trips only that circuit, not the whole board.
RCBOs follow IEC 61009 / IS 12640-2. Use 30 mA for protection against electric shock (bathrooms, sockets, outdoor circuits), 100 mA or 300 mA for equipment and fire protection. Type AC suits ordinary loads; Type A also detects pulsating DC leakage from electronics and inverter appliances. Compare in RCCB vs RCBO and mount in distribution boards.
- Two protections, one deviceEarth leakage plus overcurrent.
- 30, 100 and 300 mAPeople, equipment and fire protection.
- B and C curves, 6–63 ALighting, sockets and motors.
- Seven makesSchneider, Havells, Legrand, Hager, ABB, Siemens, L&T.
Specifications
| Current rating | 6, 10, 16, 20, 25, 32, 40, 63 A |
|---|---|
| Sensitivity (IΔn) | 10, 30, 100, 300 mA |
| Type | AC or A (A for electronic and inverter loads) |
| Curve | B or C |
| Poles | 1P+N, 2P, 3P+N / 4P |
| Breaking capacity | 6 kA or 10 kA |
| Standard | IEC 61009, IS 12640-2 |
Applications
Sockets and IT circuits.
Pumps, geysers, gardens.
- Commercial facilities
- Infrastructure & construction
- Manufacturing & engineering
- Electrical contractors
- Builders and developers
How to choose
- Rating and curve
Circuit current; B for lighting, C for motors and inductive loads.
- Sensitivity and type
30 mA for people; Type A for inverter AC, EV and electronic loads.
- Poles and make
Match the DB busbar and make.
MCB vs RCCB vs RCBO
| Device | Overload & short circuit | Earth leakage |
|---|---|---|
| MCB | Yes | No |
| RCCB | No (needs MCB backup) | Yes |
| RCBO | Yes | Yes |
Makes we can quote
Quoted in the makes below and any other make on your approved list.
Frequently asked questions
What is the full form of RCBO?
Residual Current Breaker with Overcurrent protection.
RCCB or RCBO: which is better?
An RCBO protects each circuit separately, so one fault does not cut every circuit. An RCCB with MCBs is cheaper where one leakage device covers several circuits.
Can an RCBO replace an MCB?
Yes, if it fits the DB and matches the rating and curve; it adds earth leakage protection.
Which RCBO for an AC or geyser?
Usually 16–20 A C-curve, 30 mA; Type A for inverter ACs.
Industries that use RCBO
Flat DBs with per-circuit RCBOs.
Retrofits for shock protection.
Get a quote for RCBO
Tell us the grade, size, form and quantity, or attach a drawing, BOQ or photo of the existing item. We reply with a line-by-line quotation from Kolkata, with delivery across India.
- Send your requirement Grade, size, quantity, or a BOQ, drawing or photo.
- We confirm and quote Matching make and grade, price and dispatch date, line by line.
- Dispatch from Kolkata With GST invoice, delivered to your site across India.