Mains–generator changeover for factories and buildings.

Automatic Transfer Switches (ATS)
Automatic transfer switches that change over between mains and generator or two supplies without an operator.
- Rated current
- Typically 40 A to 3200 A, by range
- Poles
- 3P or 4P
- Control
- Integrated or separate controller with voltage/frequency sensing and delays
- Standard
- IEC 60947-6-1
Buying several items? Upload your BOQ
- Electrical supply since 1991
- Leading makes, or the one you specify
- GST invoice · delivery across India
About Automatic Transfer Switches (ATS)
An ATS (automatic transfer switch) monitors the normal supply and switches the load to a standby source, usually a generator, when the normal supply fails. When the normal supply returns, it transfers back. With generator start/stop signals it forms the core of an AMF system.
Transfer switches are chosen by rated current, poles, the type of transition and the controller functions. Transfer switching equipment is covered by IEC 60947-6-1.
TPE supplies ATS units from Kolkata, and builds AMF and changeover panels around them.
- Unattended changeoverTransfers the load automatically when the main supply fails and returns when it is restored.
- 3- and 4-poleSwitch the neutral where the system needs it.
- Built-in controllersVoltage and frequency monitoring with adjustable delays.
- Approved makesABB, Schneider Electric and Socomec.
Specifications
| Rated current | Typically 40 A to 3200 A, by range |
|---|---|
| Poles | 3P or 4P |
| Control | Integrated or separate controller with voltage/frequency sensing and delays |
| Standard | IEC 60947-6-1 |
Applications
Hospitals, data rooms and lifts.
Changeover between two utility supplies.
- Commercial facilities
- Manufacturing & engineering
- Infrastructure & construction
- Hospitals
- Data centres
How to choose
- Current and poles
Match rating to the load; 4P where neutral must switch.
- Controller
Specify delays, generator start signal and test functions.
- Panel or standalone
Decide whether it goes in an AMF panel or its own enclosure.
Makes we can quote
Quoted in the makes below and any other make on your approved list.
Frequently asked questions
ATS or AMF panel?
An ATS switches between sources. An AMF panel adds generator start/stop control. See our AMF vs ATS guide.
Do I need a 4-pole ATS?
Where the generator and mains neutrals are separately earthed, a 4-pole ATS is normally used. Your electrical design decides.
How do I order?
Send rating, poles, sources, controller functions and make.
Industries that use Automatic Transfer Switches (ATS)
Automatic DG backup for critical loads.
Mains–DG changeover for production loads.
Get a quote for Automatic Transfer Switches (ATS)
Tell us the grade, size, form and quantity, or attach a drawing, BOQ or photo of the existing item. We reply with a line-by-line quotation from Kolkata, with delivery across India.
- Send your requirement Grade, size, quantity, or a BOQ, drawing or photo.
- We confirm and quote Matching make and grade, price and dispatch date, line by line.
- Dispatch from Kolkata With GST invoice, delivered to your site across India.