Manual source selection for buildings and plants.

Changeover & Load Break Switches
Manual changeover and load break switches for switching between mains and generator or isolating circuits on load.
- Rated current
- Typically 32 A to 3200 A, by range
- Poles
- 2P, 3P and 4P
- Duty
- On-load (AC-22A/AC-23A) or off-load
- Standard
- IEC 60947-3
Buying several items? Upload your BOQ
- Electrical supply since 1991
- Leading makes, or the one you specify
- GST invoice · delivery across India
About Changeover & Load Break Switches
A changeover switch lets an operator switch a load between two supplies, typically mains and generator, with an off position in between so the two sources can never be connected together. Load break switches switch and isolate circuits under load.
They are chosen by rated current, poles, utilisation category and whether they are on-load or off-load. They are covered by IEC 60947-3.
TPE supplies changeover and load break switches from Kolkata, open or enclosed.
- On-load switchingLoad break changeovers switch safely under load.
- I–O–II positionsPositive off position between the two sources.
- Enclosed or openPanel-mount or ready enclosed units.
- Approved makesL&T, C&S Electric, Salzer, Socomec and Indo Asian.
Specifications
| Rated current | Typically 32 A to 3200 A, by range |
|---|---|
| Poles | 2P, 3P and 4P |
| Duty | On-load (AC-22A/AC-23A) or off-load |
| Standard | IEC 60947-3 |
Applications
Load break isolation of feeders.
Selecting between two incomers.
How to choose
- Rating
Match current to the incomer.
- On-load or off-load
Use on-load rated switches if switching under load.
- Poles
4P where the neutral must switch.
- Manual or automatic
For unattended changeover choose an ATS instead.
Makes we can quote
Quoted in the makes below and any other make on your approved list.
Frequently asked questions
Manual changeover or ATS?
A manual changeover needs someone to operate it. An ATS switches automatically.
What does on-load rated mean?
The switch can make and break the rated load current safely, per its utilisation category.
How do I order?
Send rating, poles, duty, open or enclosed, make and quantity.
Industries that use Changeover & Load Break Switches
Mains–generator changeover and feeder isolation.
Get a quote for Changeover & Load Break Switches
Tell us the grade, size, form and quantity, or attach a drawing, BOQ or photo of the existing item. We reply with a line-by-line quotation from Kolkata, with delivery across India.
- Send your requirement Grade, size, quantity, or a BOQ, drawing or photo.
- We confirm and quote Matching make and grade, price and dispatch date, line by line.
- Dispatch from Kolkata With GST invoice, delivered to your site across India.