Earth fault protection.

Earth Leakage Relays (ELR)
Earth leakage relays (ELR) with core balance CTs for adjustable earth fault protection of MCCB and ACB feeders in LT panels.
- Sensitivity
- About 30 mA to 30 A, adjustable
- Time delay
- Instantaneous to about 1–5 s, adjustable
- Sensor
- Core balance CT, window size by cable/busbar
- Output
- Changeover relay contact to trip breaker
Buying several items? Upload your BOQ
- Electrical supply since 1991
- Leading makes, or the one you specify
- GST invoice · delivery across India
About Earth Leakage Relays (ELR)
An earth leakage relay (ELR) measures leakage current through a core balance CT (CBCT) placed around all live conductors of a feeder. When leakage exceeds the set level for the set time, its output contact trips the MCCB or ACB through a shunt or undervoltage release.
Unlike a fixed RCCB, an ELR lets you set sensitivity and delay, so large feeders and incomers can have earth fault protection with selectivity. IEC 60947-2 Annex M covers residual current devices of this type. ELRs are fitted in PCC and MCC panels.
- Adjustable sensitivityAbout 30 mA to 30 A.
- Time delayFor selectivity.
- Works with any breakerTrips via shunt or UV release.
- Four makesSchneider, Siemens, Selec, Elmeasure.
Specifications
| Sensitivity | About 30 mA to 30 A, adjustable |
|---|---|
| Time delay | Instantaneous to about 1–5 s, adjustable |
| Sensor | Core balance CT, window size by cable/busbar |
| Output | Changeover relay contact to trip breaker |
| Supply | 24–240 V AC/DC auxiliary |
| Mounting | Panel (96 × 96 / 48 × 96) or DIN rail |
Applications
Insulation deterioration alarm.
Leakage monitoring.
How to choose
- Sensitivity and delay
Protection level and selectivity.
- CBCT size
Window must pass all phase and neutral conductors.
- Breaker interface
Shunt or UV release on the breaker.
Makes we can quote
Quoted in the makes below and any other make on your approved list.
Frequently asked questions
What is the difference between an ELR and an RCCB?
An RCCB is a fixed device with its own contacts; an ELR is an adjustable relay that trips a separate breaker using a CBCT.
Why is a CBCT used?
It measures the vector sum of all conductor currents; any imbalance is leakage to earth.
Does the earth conductor pass through the CBCT?
No. Pass phases and neutral only; the protective earth stays outside.
Industries that use Earth Leakage Relays (ELR)
Incomer earth fault protection.
Feeder leakage monitoring.
Get a quote for Earth Leakage Relays (ELR)
Tell us the grade, size, form and quantity, or attach a drawing, BOQ or photo of the existing item. We reply with a line-by-line quotation from Kolkata, with delivery across India.
- Send your requirement Grade, size, quantity, or a BOQ, drawing or photo.
- We confirm and quote Matching make and grade, price and dispatch date, line by line.
- Dispatch from Kolkata With GST invoice, delivered to your site across India.