Heat treatment and melting.

Thermocouples
Thermocouples (K, J, R, S, B, N, T) with mineral-insulated, ceramic and metal sheaths for furnaces, ovens and process temperature.
- Types
- K, J, T, E, N, R, S, B
- Range
- About −200 °C to 1,700 °C by type
- Sheath
- SS 310/316, Inconel, ceramic, MI cable
- Head
- Aluminium or SS, with terminal block or transmitter
Buying several items? Upload your BOQ
- Electrical supply since 1991
- Leading makes, or the one you specify
- GST invoice · delivery across India
About Thermocouples
A thermocouple produces a millivolt signal from two dissimilar metals joined at the hot end. Type K covers general use to about 1,200 °C; J suits lower ranges; R, S and B (platinum) handle furnaces up to about 1,600–1,700 °C.
Connect with matching thermocouple extension cable, and read with a PID controller or transmitter. Compare with RTDs in the thermocouple vs RTD guide.
- All common typesK, J, T, N, R, S, B.
- Up to about 1,700 °CNoble metal types for high heat.
- Custom lengthsSheath and head as needed.
- Two makesABB and Siemens, custom builds on request.
Specifications
| Types | K, J, T, E, N, R, S, B |
|---|---|
| Range | About −200 °C to 1,700 °C by type |
| Sheath | SS 310/316, Inconel, ceramic, MI cable |
| Head | Aluminium or SS, with terminal block or transmitter |
| Standard | IEC 60584 |
Applications
Barrels and dies.
Flue and steam.
- Steel & metals
- Manufacturing & engineering
- Power & utilities
- Glass and ceramics
How to choose
- Type and range
Maximum temperature.
- Sheath and length
Media and insertion depth.
- Termination
Head, cable or transmitter.
Thermocouple types
| Type | Approx. range | Use |
|---|---|---|
| J | Up to ~750 °C | Plastics, low temperature |
| K | Up to ~1,200 °C | General purpose |
| N | Up to ~1,250 °C | Stable at high temperature |
| R / S | Up to ~1,600 °C | Furnaces, glass |
| B | Up to ~1,700 °C | Very high temperature |
Makes we can quote
Quoted in the makes below and any other make on your approved list.
Frequently asked questions
Thermocouple or RTD?
Thermocouples for high temperatures and fast response; RTDs for better accuracy below about 600 °C.
Why use extension cable?
Copper wire creates errors; matching alloys carry the signal correctly.
Industries that use Thermocouples
Furnace temperature.
Process heating.
Get a quote for Thermocouples
Tell us the grade, size, form and quantity, or attach a drawing, BOQ or photo of the existing item. We reply with a line-by-line quotation from Kolkata, with delivery across India.
- Send your requirement Grade, size, quantity, or a BOQ, drawing or photo.
- We confirm and quote Matching make and grade, price and dispatch date, line by line.
- Dispatch from Kolkata With GST invoice, delivered to your site across India.