Routine PD tests.

Testing & Measuring Instruments
Partial Discharge Test Set
Partial discharge (PD) measurement systems for transformers, cables, switchgear and instrument transformers.
- Measurement
- Apparent charge pC, IEC 60270
- Sensitivity
- Down to < 1 pC in shielded labs
- Components
- Coupling capacitor, measuring impedance, PD detector, calibrator
- Online methods
- HFCT, TEV, UHF and acoustic sensors
Buying several items? Upload your BOQ
- Electrical supply since 1991
- Leading makes, or the one you specify
- GST invoice · delivery across India
About Partial Discharge Test Set
Partial discharges are small sparks within voids or along surfaces in insulation that do not bridge the electrodes but erode insulation over time. A PD test set measures apparent charge in picocoulombs per IEC 60270, with a coupling capacitor, measuring impedance and an AC HV source.
Phase-resolved patterns help identify internal, surface and corona discharge. PD testing is part of routine tests on cast resin and oil transformers, CTs, cables and HV switchgear.
- Apparent charge in pCIEC 60270 measurement.
- Factory and siteLab systems and online detectors.
- Phase-resolved patternsIdentify PD type.
- Makes on requestQuoted in your specified make.
Specifications
| Measurement | Apparent charge pC, IEC 60270 |
|---|---|
| Sensitivity | Down to < 1 pC in shielded labs |
| Components | Coupling capacitor, measuring impedance, PD detector, calibrator |
| Online methods | HFCT, TEV, UHF and acoustic sensors |
| Analysis | Phase-resolved PD (PRPD) patterns |
Applications
Factory PD tests.
Online switchgear PD surveys.
- Power & utilities
- Transformer manufacturers
- Cable manufacturers
- Testing laboratories
How to choose
- Factory or online
Lab system or portable online detector.
- Sensitivity
Background noise and shielding at site.
- HV source
Matching AC test source and coupling capacitor.
Makes we can quote
Quoted in the make and grade you specify, or an approved equivalent.
Tell us the make and gradeFrequently asked questions
What is partial discharge?
A localised breakdown in part of the insulation that slowly damages it.
What PD level is acceptable?
It depends on the product standard; cast resin transformers often require ≤ 10 pC.
Industries that use Partial Discharge Test Set
Routine tests.
Condition surveys.
Get a quote for Partial Discharge Test Set
Tell us the grade, size, form and quantity, or attach a drawing, BOQ or photo of the existing item. We reply with a line-by-line quotation from Kolkata, with delivery across India.
- Send your requirement Grade, size, quantity, or a BOQ, drawing or photo.
- We confirm and quote Matching make and grade, price and dispatch date, line by line.
- Dispatch from Kolkata With GST invoice, delivered to your site across India.