Withstand after laying and jointing.

Testing & Measuring Instruments
AC / DC High Voltage Test Sets (incl. Combined AC & DC)
AC, DC and combined AC/DC high voltage test sets for withstand testing of cables, switchgear, transformers and machines.
- Output
- AC up to 100 kV+; DC up to 100–200 kV
- Current
- mA rated by kVA of set
- Metering
- kV, leakage µA/mA, timer
- Protection
- Overcurrent trip, zero-start interlock, earthing
Buying several items? Upload your BOQ
- Electrical supply since 1991
- Leading makes, or the one you specify
- GST invoice · delivery across India
About AC / DC High Voltage Test Sets (incl. Combined AC & DC)
An HV test set applies a high AC or DC voltage for a set time to prove that insulation withstands it without breakdown, while measuring leakage current. AC tests stress insulation as in service; DC tests need a smaller set and suit long cables and rotating machines.
For XLPE cables, very-low-frequency (VLF) AC is preferred over DC. Before an HV test, check insulation resistance; for diagnostic loss measurement use a tan delta test set.
- AC and DCWithstand and leakage current.
- To 100 kV and morePortable and lab sets.
- Leakage meteringµA/mA readout and trip.
- Two makesMegger and Motwane.
Specifications
| Output | AC up to 100 kV+; DC up to 100–200 kV |
|---|---|
| Current | mA rated by kVA of set |
| Metering | kV, leakage µA/mA, timer |
| Protection | Overcurrent trip, zero-start interlock, earthing |
| Configurations | AC, DC, combined AC/DC, VLF |
Applications
Power-frequency withstand.
Winding withstand tests.
- Power & utilities
- Motor & transformer rewinding
- Manufacturing & engineering
- Cable manufacturers
- Testing laboratories
How to choose
- AC, DC or VLF
AC/VLF for XLPE cables; DC for older cables and machines.
- Voltage and kVA
Test voltage and capacitance of the test object.
- Portability
Portable for site; larger for labs.
HV test methods
| Method | Best for | Note |
|---|---|---|
| Power-frequency AC | Switchgear, transformers, short cables | Large kVA for long cables |
| DC | Machines, older paper cables | Not for aged XLPE |
| VLF (0.1 Hz) | XLPE cables | Small set, AC stress |
Makes we can quote
Quoted in the makes below and any other make on your approved list.
Frequently asked questions
AC or DC HV test?
AC stresses insulation like service; DC needs less power. XLPE cables should not get high DC tests.
What test voltage for an 11 kV panel?
Power-frequency withstand of 28 kV for 1 minute is typical under IEC 62271; check your specification.
Industries that use AC / DC High Voltage Test Sets (incl. Combined AC & DC)
Cable and switchgear tests.
Routine tests.
Get a quote for AC / DC High Voltage Test Sets (incl. Combined AC & DC)
Tell us the grade, size, form and quantity, or attach a drawing, BOQ or photo of the existing item. We reply with a line-by-line quotation from Kolkata, with delivery across India.
- Send your requirement Grade, size, quantity, or a BOQ, drawing or photo.
- We confirm and quote Matching make and grade, price and dispatch date, line by line.
- Dispatch from Kolkata With GST invoice, delivered to your site across India.