Periodic oil checks.

Testing & Measuring Instruments
High Voltage Vacuum Tester / Oil Insulation Test Set
Automatic and manual transformer oil BDV test sets to 60, 80 and 100 kV, and HV vacuum testers.
- Test voltage
- 0–60, 0–80 or 0–100 kV AC
- Electrodes
- Mushroom or spherical, 2.5 mm gap
- Standards
- IS 6792, IEC 60156, ASTM D877 / D1816
- Operation
- Automatic or manual with motorised ramp
Buying several items? Upload your BOQ
- Electrical supply since 1991
- Leading makes, or the one you specify
- GST invoice · delivery across India
About High Voltage Vacuum Tester / Oil Insulation Test Set
An oil breakdown voltage (BDV) test set raises AC voltage across a 2.5 mm electrode gap in a sample of transformer oil until it breaks down. IS 6792 / IEC 60156 averages six breakdowns. Low BDV means water or particles in the oil.
Automatic sets control the ramp rate, stirring and rest times for repeatable results. The oil BDV test guide explains procedure and limits; we also supply transformer oil and silica gel breathers. HV vacuum testers check vacuum interrupter integrity.
- 60 / 80 / 100 kVBreakdown voltage of insulating oil.
- Automatic sequencesIS 6792, IEC 60156, ASTM D877/D1816.
- Printer and memoryAverage of six breakdowns.
- Two makesMegger and Motwane.
Specifications
| Test voltage | 0–60, 0–80 or 0–100 kV AC |
|---|---|
| Electrodes | Mushroom or spherical, 2.5 mm gap |
| Standards | IS 6792, IEC 60156, ASTM D877 / D1816 |
| Operation | Automatic or manual with motorised ramp |
| Output | Printer, memory, average BDV |
Applications
Before and after filtration.
Interrupter integrity (vacuum tester).
- Power & utilities
- Motor & transformer rewinding
- Transformer manufacturers
- Oil filtration contractors
How to choose
- Maximum voltage
60 kV for routine; 80–100 kV for new and EHV oil.
- Automatic or manual
Automatic for repeatable standard tests.
- Standards
Programmed standards needed.
Makes we can quote
Quoted in the makes below and any other make on your approved list.
Frequently asked questions
What BDV is acceptable?
It depends on equipment voltage class and whether the oil is new or in service. IS 1866 / IEC 60422 set the limits, and new oil must meet higher values than in-service oil.
Why does BDV fall?
Moisture and particles.
Industries that use High Voltage Vacuum Tester / Oil Insulation Test Set
Oil condition checks.
Oil acceptance after repair.
Get a quote for High Voltage Vacuum Tester / Oil Insulation Test Set
Tell us the grade, size, form and quantity, or attach a drawing, BOQ or photo of the existing item. We reply with a line-by-line quotation from Kolkata, with delivery across India.
- Send your requirement Grade, size, quantity, or a BOQ, drawing or photo.
- We confirm and quote Matching make and grade, price and dispatch date, line by line.
- Dispatch from Kolkata With GST invoice, delivered to your site across India.