Tests
Ratio, ratio error, phase angle, polarity, burden, excitation/knee-point, winding resistance
CT ratios
Up to several thousand to 1 or 5 A
Excitation voltage
Up to 2 kV on knee-point models
Accuracy classes
Metering 0.1–1; protection 5P, 10P, PS

Buying several items? Upload your BOQ

  • Electrical supply since 1991
  • Leading makes, or the one you specify
  • GST invoice · delivery across India

About Current & Potential Transformer Test Sets

A CT/PT test set verifies instrument transformers: turns ratio, ratio error, phase displacement, polarity, winding resistance, burden and, for protection CTs, the excitation curve and knee-point voltage. IS 16227 / IEC 61869 define accuracy classes.

Automatic analysers run all tests from one connection. See the CT vs PT guide; for reference standards in a meter lab see precision CT and PT, and for in-service units see current transformers.

  • Ratio and phase errorAccuracy class verification.
  • Knee-pointExcitation curve of protection CTs.
  • Polarity and burdenFull CT/PT checks.
  • Two makesMegger and Motwane.

Specifications

TestsRatio, ratio error, phase angle, polarity, burden, excitation/knee-point, winding resistance
CT ratiosUp to several thousand to 1 or 5 A
Excitation voltageUp to 2 kV on knee-point models
Accuracy classesMetering 0.1–1; protection 5P, 10P, PS
StandardsIS 16227, IEC 61869

Applications

CT/PT manufacturing

Routine accuracy tests.

Substation commissioning

Instrument transformer checks.

Metering

Accuracy verification.

Used in

How to choose

  1. CT, PT or both

    Functions needed.

  2. Knee-point voltage

    Excitation voltage above the CT knee.

  3. Automatic analyser

    For production and fast commissioning.

Makes we can quote

Quoted in the makes below and any other make on your approved list.

Frequently asked questions

What is the CT knee-point?

The excitation voltage at which a 10% rise in voltage causes a 50% rise in excitation current.

Why test CT polarity?

Wrong polarity causes protection mis-operation and wrong metering.

Industries that use Current & Potential Transformer Test Sets

Utilities

Commissioning tests.

Manufacturers

Routine tests.

Get a quote for Current & Potential Transformer Test Sets

Tell us the grade, size, form and quantity, or attach a drawing, BOQ or photo of the existing item. We reply with a line-by-line quotation from Kolkata, with delivery across India.

  1. Send your requirement Grade, size, quantity, or a BOQ, drawing or photo.
  2. We confirm and quote Matching make and grade, price and dispatch date, line by line.
  3. Dispatch from Kolkata With GST invoice, delivered to your site across India.
Prefer WhatsApp?
PDF, Excel, Word, CSV, images · 5 files · 4 MB
Add email or phone so we can reply.
Add company name (optional)
Files are sent privately to our sales team.