Routine accuracy tests.

Testing & Measuring Instruments
Current & Potential Transformer Test Sets
CT and PT test sets for ratio, polarity, phase angle error, burden and knee-point, including automatic CT/PT analysers.
- Tests
- Ratio, ratio error, phase angle, polarity, burden, excitation/knee-point, winding resistance
- CT ratios
- Up to several thousand to 1 or 5 A
- Excitation voltage
- Up to 2 kV on knee-point models
- Accuracy classes
- Metering 0.1–1; protection 5P, 10P, PS
Buying several items? Upload your BOQ
- Electrical supply since 1991
- Leading makes, or the one you specify
- GST invoice · delivery across India
About Current & Potential Transformer Test Sets
A CT/PT test set verifies instrument transformers: turns ratio, ratio error, phase displacement, polarity, winding resistance, burden and, for protection CTs, the excitation curve and knee-point voltage. IS 16227 / IEC 61869 define accuracy classes.
Automatic analysers run all tests from one connection. See the CT vs PT guide; for reference standards in a meter lab see precision CT and PT, and for in-service units see current transformers.
- Ratio and phase errorAccuracy class verification.
- Knee-pointExcitation curve of protection CTs.
- Polarity and burdenFull CT/PT checks.
- Two makesMegger and Motwane.
Specifications
| Tests | Ratio, ratio error, phase angle, polarity, burden, excitation/knee-point, winding resistance |
|---|---|
| CT ratios | Up to several thousand to 1 or 5 A |
| Excitation voltage | Up to 2 kV on knee-point models |
| Accuracy classes | Metering 0.1–1; protection 5P, 10P, PS |
| Standards | IS 16227, IEC 61869 |
Applications
Instrument transformer checks.
Accuracy verification.
- Power & utilities
- Manufacturing & engineering
- CT/PT manufacturers
- Testing laboratories
How to choose
- CT, PT or both
Functions needed.
- Knee-point voltage
Excitation voltage above the CT knee.
- Automatic analyser
For production and fast commissioning.
Makes we can quote
Quoted in the makes below and any other make on your approved list.
Frequently asked questions
What is the CT knee-point?
The excitation voltage at which a 10% rise in voltage causes a 50% rise in excitation current.
Why test CT polarity?
Wrong polarity causes protection mis-operation and wrong metering.
Industries that use Current & Potential Transformer Test Sets
Commissioning tests.
Routine tests.
Get a quote for Current & Potential Transformer Test Sets
Tell us the grade, size, form and quantity, or attach a drawing, BOQ or photo of the existing item. We reply with a line-by-line quotation from Kolkata, with delivery across India.
- Send your requirement Grade, size, quantity, or a BOQ, drawing or photo.
- We confirm and quote Matching make and grade, price and dispatch date, line by line.
- Dispatch from Kolkata With GST invoice, delivered to your site across India.