Protection scheme tests.

Testing & Measuring Instruments
Relay Test Set
Secondary and primary injection relay test sets for overcurrent, earth fault, distance and differential protection.
- Current
- Secondary: 0–30 A+ per phase; primary: 100 A–5 kA
- Voltage
- 0–300 V per phase on three-phase sets
- Phase control
- 0–360° phase angle, frequency
- Timing
- ms resolution with start/stop inputs
Buying several items? Upload your BOQ
- Electrical supply since 1991
- Leading makes, or the one you specify
- GST invoice · delivery across India
About Relay Test Set
A relay test set injects current and voltage to check that a protection relay picks up and trips at the right setting and time. Secondary injection works at relay input level (1 A / 5 A); primary injection passes hundreds or thousands of amps through CTs to test the whole chain.
Three-phase sets test distance, differential and directional relays with phase angle control. For breaker trip timing use a digital timer interval meter; for single-function work see the AC/DC injection test set.
- Secondary injectionTest relays with CT/VT-level signals.
- Primary injectionHigh current through the whole scheme.
- TimingTrip time with contact inputs.
- Two makesMegger and Motwane.
Specifications
| Current | Secondary: 0–30 A+ per phase; primary: 100 A–5 kA |
|---|---|
| Voltage | 0–300 V per phase on three-phase sets |
| Phase control | 0–360° phase angle, frequency |
| Timing | ms resolution with start/stop inputs |
| Relays | Overcurrent, earth fault, distance, differential, directional |
Applications
Periodic relay calibration.
Relay panel testing.
- Power & utilities
- Manufacturing & engineering
- Protection testing contractors
How to choose
- Secondary or primary
Primary for CT-to-breaker scheme tests.
- Phases
Three-phase for distance and differential.
- Automation
Software test plans for numerical relays.
Makes we can quote
Quoted in the makes below and any other make on your approved list.
Frequently asked questions
Secondary or primary injection?
Secondary checks the relay alone; primary checks CTs, wiring, relay and breaker together.
Can it test numerical relays?
Yes; three-phase sets with software test distance and differential functions.
Industries that use Relay Test Set
Protection maintenance.
HT substation commissioning.
Get a quote for Relay Test Set
Tell us the grade, size, form and quantity, or attach a drawing, BOQ or photo of the existing item. We reply with a line-by-line quotation from Kolkata, with delivery across India.
- Send your requirement Grade, size, quantity, or a BOQ, drawing or photo.
- We confirm and quote Matching make and grade, price and dispatch date, line by line.
- Dispatch from Kolkata With GST invoice, delivered to your site across India.