Kolkata · Since 1991Shipping across IndiaGST 19AESPK5930K1ZU
+91 82403 34928

Find your electrical requirement

Share an item reference or photo for help →
Relay Test Set product-type reference

Testing & Measuring Instruments

Relay Test Set

Secondary and primary injection relay test sets for overcurrent, earth fault, distance and differential protection.

Current
Secondary: 0–30 A+ per phase; primary: 100 A–5 kA
Voltage
0–300 V per phase on three-phase sets
Phase control
0–360° phase angle, frequency
Timing
ms resolution with start/stop inputs

Buying several items? Upload your BOQ

  • Electrical supply since 1991
  • Leading makes, or the one you specify
  • GST invoice · delivery across India

About Relay Test Set

A relay test set injects current and voltage to check that a protection relay picks up and trips at the right setting and time. Secondary injection works at relay input level (1 A / 5 A); primary injection passes hundreds or thousands of amps through CTs to test the whole chain.

Three-phase sets test distance, differential and directional relays with phase angle control. For breaker trip timing use a digital timer interval meter; for single-function work see the AC/DC injection test set.

  • Secondary injectionTest relays with CT/VT-level signals.
  • Primary injectionHigh current through the whole scheme.
  • TimingTrip time with contact inputs.
  • Two makesMegger and Motwane.

Specifications

CurrentSecondary: 0–30 A+ per phase; primary: 100 A–5 kA
Voltage0–300 V per phase on three-phase sets
Phase control0–360° phase angle, frequency
Timingms resolution with start/stop inputs
RelaysOvercurrent, earth fault, distance, differential, directional

Applications

Substation commissioning

Protection scheme tests.

Maintenance

Periodic relay calibration.

Panel builders

Relay panel testing.

Used in

How to choose

  1. Secondary or primary

    Primary for CT-to-breaker scheme tests.

  2. Phases

    Three-phase for distance and differential.

  3. Automation

    Software test plans for numerical relays.

Makes we can quote

Quoted in the makes below and any other make on your approved list.

Frequently asked questions

Secondary or primary injection?

Secondary checks the relay alone; primary checks CTs, wiring, relay and breaker together.

Can it test numerical relays?

Yes; three-phase sets with software test distance and differential functions.

Industries that use Relay Test Set

Utilities

Protection maintenance.

Industrial plants

HT substation commissioning.

Get a quote for Relay Test Set

Tell us the grade, size, form and quantity, or attach a drawing, BOQ or photo of the existing item. We reply with a line-by-line quotation from Kolkata, with delivery across India.

  1. Send your requirement Grade, size, quantity, or a BOQ, drawing or photo.
  2. We confirm and quote Matching make and grade, price and dispatch date, line by line.
  3. Dispatch from Kolkata With GST invoice, delivered to your site across India.
Prefer WhatsApp?